Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Clin Endocrinol Metab ; 107(5): e1890-e1898, 2022 04 19.
Artigo em Inglês | MEDLINE | ID: mdl-35038731

RESUMO

CONTEXT: Atypical femoral fractures (AFFs) are very rare atraumatic or mild trauma fractures in the subtrochanteric region or femoral shaft. Some unique genetic variants in Asian populations might confer susceptibility to AFF, since the incidence of AFFs is higher in Asian populations. OBJECTIVE: Because rare variants have been found to be causative in some diseases and the roles of osteomalacia causative genes have not been reported, we investigated rare variants in genes causing abnormal mineralization. METHODS: Exome sequencing was performed to detect variants in gene coding and boundary regions, and the frequencies of deleterious rare alleles were compared between Japanese patients with AFF (n = 42) and controls of the 4.7KJPN panel of Tohoku Medical Megabank by whole genome sequencing (n = 4773). RESULTS: The frequency of the deleterious rare allele of ENPP1 was significantly increased in AFF (P = .0012, corrected P [Pc] = .0155, OR 4.73, 95% CI 2.15-10.40). In multigene panel analysis, the frequencies of deleterious rare alleles of candidate genes were increased in AFF (P = .0025, OR 2.72, 95% CI 1.49-4.93). Principal component analysis of bone metabolism markers identified a subgroup of patients with AFF with higher frequencies of deleterious rare alleles in ENPP1 (P = 4.69 × 10-5, Pc = .0006, OR 8.47, 95% CI 3.76-19.09) and the candidate genes (P = 1.08 × 10-5, OR 5.21, 95% CI 2.76-9.86). CONCLUSION: AFF is associated with genes including ENPP1 that cause abnormal mineralization, suggesting that osteomalacia is an underlying condition predisposing to AFF and that higher incident rates of AFFs in Asian populations might be explained by the genetic risk factors including ENPP1.


Assuntos
Conservadores da Densidade Óssea , Doenças Ósseas , Raquitismo Hipofosfatêmico Familiar , Fraturas do Fêmur , Osteomalacia , Alelos , Conservadores da Densidade Óssea/efeitos adversos , Doenças Ósseas/genética , Difosfonatos/efeitos adversos , Raquitismo Hipofosfatêmico Familiar/complicações , Feminino , Fraturas do Fêmur/epidemiologia , Fraturas do Fêmur/genética , Humanos , Masculino , Osteomalacia/genética
2.
J Orthop Res ; 25(7): 884-93, 2007 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-17343280

RESUMO

We previously developed a novel ultrasound assessment system featuring wavelet transform to evaluate the material properties of articular cartilage. We aimed in this study to demonstrate the feasibility of quantitative evaluation of meniscus using ultrasound and to elucidate the relationships between its acoustic, mechanical, and biochemical properties. Meniscal disc specimens from mature pigs were assessed by ultrasound and compression testing, and their correlation was analyzed. A positive correlation was found between the ultrasound signal intensity and apparent Young's modulus (r=0.61). Subsequently, the porcine meniscal discs were treated with various enzymes and then characterized by ultrasound, by compression tests, by biochemical analyses, and by histology and immunohistochemistry. The signal intensity was decreased not by hyaluronidase but by collagenase treatment. Hyaluronidase-treated menisci showed a discrepancy between acoustic and mechanical properties, suggesting that the ultrasound reflection could not detect a reduction in proteoglycan content. Also, ultrasound signal intensity could only reflect superficial layers of the material. Several limitations exist at present, and further studies and improvements of the device are required. However, given the noninvasive nature and the requirement of only small equipment, this ultrasound assessment system will be an instrumental diagnostic tool for meniscal function in both research and clinical fields.


Assuntos
Cartilagem Articular/fisiologia , Meniscos Tibiais/fisiologia , Suínos , Animais , Cartilagem Articular/diagnóstico por imagem , Cartilagem Articular/efeitos dos fármacos , Colagenases/farmacologia , Força Compressiva/efeitos dos fármacos , Força Compressiva/fisiologia , Glicosaminoglicanos/metabolismo , Hialuronoglucosaminidase/farmacologia , Hidroxiprolina/metabolismo , Meniscos Tibiais/diagnóstico por imagem , Meniscos Tibiais/efeitos dos fármacos , Reologia/métodos , Ultrassom , Ultrassonografia , Água/metabolismo
3.
Arthritis Res Ther ; 6(6): R492-504, 2004.
Artigo em Inglês | MEDLINE | ID: mdl-15535827

RESUMO

We investigated quantitative changes over time in ultrasound signal intensity (an index of stiffness), signal duration (an index of surface irregularity), and interval between signals (an index of thickness) of plug cartilage in an animal model of autologous osteochondral grafting. A full-thickness osteochondral plug was surgically removed and replaced in male Japanese white rabbits (n = 22). Specimens obtained at day 0 and weeks 2, 4, 8, 12 and 24 postoperatively were assessed using an ultrasound system and by macroscopic and histological evaluation (modified Mankin's score). Histology revealed that the plug sank until 2 weeks postoperatively, and that newly formed cartilage-like tissue covered the plug, but at 24 weeks the tissue detached. The plug itself survived well throughout the period of observation. Although the signal intensity at the plug site was same as that in the sham operated contralateral knee at day 0, from 2 to 24 weeks postoperatively it was less than that in the sham knee. At 8 weeks, this difference was significant (P < 0.05). Modified Mankin's score revealed early degenerative changes at the site, but macroscopic examination did not. Signal intensity correlated significantly with score (both at day 0 and at the five postoperative time points [P < 0.05, r = -0.91] and as a whole [P < 0.05, r = -0.36]). Signal intensity also significantly correlated with the individual subscores for 'cartilage structure' (P < 0.05, r = -0.32) and 'cartilage cells' (P < 0.05, r = -0.30) from the modified Mankin's score, but not significantly with subscores for 'staining' and 'tidemark'. Signal duration correlated significantly with total score (as a whole [P < 0.05, r = 0.34]), but not significantly with the score for cartilage structure (P = 0.0557, r = 0.29). The interval between signals reflected well the actual thickness of the plug site. The significant relationships between ultrasound signal intensity and scores suggest that early degenerative changes in plug cartilage and cartilage-like tissue, especially in the superficial layer, are detectable by high-frequency ultrasound assessment.


Assuntos
Cartilagem Articular/transplante , Animais , Cartilagem Articular/diagnóstico por imagem , Cartilagem Articular/patologia , Articulação do Joelho/cirurgia , Masculino , Modelos Animais , Maleabilidade , Coelhos , Distribuição Aleatória , Índice de Gravidade de Doença , Transplante Autólogo , Ultrassonografia , Cicatrização
4.
J Biomed Mater Res ; 60(4): 556-63, 2002 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-11948514

RESUMO

New bioactive composites consisting of partially crystallized glass beads as inorganic fillers and poly(methyl methacrylate) (PMMA) as an organic matrix were developed. Two kinds of partially crystallized glass beads, designated Cry820 and Cry850, were newly prepared by the heating of MgO-CaO-SiO(2)-P(2)O(5) glass at 820 and 850 degrees C, respectively. The glass beads were mixed with PMMA to form two new composites designated Cry820C and Cry850C, respectively. The goal of this study was to produce a highly osteoconductive and mechanically strong composite cement with these new fillers. A previously reported composite cement designated AWC, which was composed of apatite- and wollastonite-containing glass ceramic (AW-GC) as a powder filler and the same PMMA polymer used in the new composites, was used as a reference material. The quantity of filler added to each composite was 70 wt %. The bending strength of Cry820C was significantly higher than that of Cry850C. Composites were packed into intramedullary canals of rat tibiae to evaluate their osteoconductivity, as determined by an affinity index. The affinity index, which equaled the length of bone in direct contact with the composite surface expressed as a percentage of the total length of the composite surface, was calculated for each composite. The rats were euthanized at 4, 8, and 25 weeks after implantation. At each time interval studied, Cry820C showed a significantly higher affinity index than AWC up to 25 weeks after implantation. Cry850C showed a significantly higher affinity index than AWC up to 8 weeks and a higher affinity index than AWC at 25 weeks, although the difference was not significant. The values for each composite increased significantly with time up to 25 weeks. Our study revealed that the higher osteoconductivity of the new composites was due to the larger quantity of the glassy phase of the crystallized glass beads at the composite surface and the lower solubility of the PMMA powder to methyl methacrylate monomer. In addition, the spherical shape of the crystallized glass beads gave the new composites strong enough mechanical properties to be useful under weight-bearing conditions. The new composites show promise as alternatives, with improved properties, to conventional PMMA bone cement.


Assuntos
Cimentos Ósseos/química , Vidro/química , Polimetil Metacrilato/química , Animais , Materiais Biocompatíveis/química , Materiais Biocompatíveis/metabolismo , Cimentos Ósseos/metabolismo , Osso e Ossos/metabolismo , Osso e Ossos/ultraestrutura , Cristalização , Masculino , Mecânica , Microscopia Eletrônica de Varredura , Polimetil Metacrilato/metabolismo , Ratos , Ratos Wistar , Tíbia/ultraestrutura
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...